Coleman Hot Tub Error Code E03



Do not use your hot tub when this error code pops up. It means the water is too hot, and may even scald you. The possible causes are plentiful, but you can check a few simple things. Clean your circulation system and filter. Rule number 1 is to always (not with pressurized filter cannister) fill the hot tub after a drain down by placing the hose pipe in the filter housing (remove filter) this fills the hot tub from inside to outside, rather than placing the hose pipe in tub, (this fills outside to inside) and is the primary cause of FLO errors. If have a problem, query, or need advice about your Lay-Z-Spa please visited our troubleshooting area by clicking on the relevant section below: I have an issue with my Lay-Z-Spa pump. I have an issue with my Lay-Z-Spa inflatable liner. I need help with my Lay-Z-Spa cover. I need help with my Lay-Z-Spa inflatable lid.

  1. Coleman Spas are programmed to filter twice a day. The first cycle starts six minutes after the spa is turned on, and the second cycle runs 12 hours later. The default filtering is for two hours, but you can change this to suit your needs. Filtration time can be anywhere from one to six hours.
  2. Feb 17, 2016 - Answers to common Lay-Z-Spa issues as well as advice and troubleshooting from the official home of Lay-Z-Spa.

Wondering what your spa is trying to tell you? Below is a list of common error codes from the top manufacturers of control equipment for hot tubs.

Note: The control system brand name is usually different from the hot tub brand name. You can often determine the make of the control system by looking inside the spa's equipment area.

Disclaimer: Although we hope this information will be useful, error codes are subject to change without notice. We make no representation as to the accuracy or completeness of this data and aren't responsible for errors or omissions. Refer to your owner's manual.

Nov 7, 2020 - All food and drinks here are edible and drinkable. See more ideas about sims 4, sims, sims 4 studio. Sims 4 custom food interactions mod. MC Command Center. This is the mod of all mods, the top of the totem, the cream of the crop! I'm showing you the Food Delivery Service Mod by LittleMsSam. This mod adds the cooked food into the list of food you can call have delivered. It has 11 new dramatic scenarios that bring excitement and controversy to every.

Error & LCD Window Message Codes:

ACC (Applied Computer Controls)

CoLd = Temperature in the spa heater housing is below 40° F. Status of the heater element is unknown. The low speed pump or circ pump will operate continuously until the temperature rises above 45° F.
OH = Over heat. The spa is at a temperature above 108° . Do not use spa when temperature is flashing or the OH message is displayed.
HLoH = Hi Limit Over Heat. Hi limit sensor is disconnected or shorted or the spa temperature is above 112° F.
SEoP = Sensor open or disconnected. Heater disabled but the spa is operational.
SESH = Sensor short, nonfunctional. Heater disabled but the spa is operational.
PSoC = Pressure switch open with circulating pump.
PSoL = Pressure switch open with low pump.
PSoH = Pressure switch open with high pump.
ToE = Time out error. Rare system error. Spa unusable. Contact ACC.

Balboa

(used by LifeCast Spas and many other hot tubs)

pd = Power supply, unit running on battery backup
OH = Sensors reading 112-118° F.
OHH = Overheat. Spa has shut down. One sensor has detected 118° F at heater.
OHS = Overheat. Spa has shut down. One sensor has detected 110°F.
Flo = Improper flow or pressure switch malfunction
Cool = Water temp 20° below set point
ICE = Potential freeze condition has been detected
Sn1 = Hi-limit sensor malfunction
Sn3 = Temp sensor malfunction
SnA = Spa is shut down. Sensor plugged into jack A is not working.
Snb = Spa is shut down. Sensor plugged into jack B is not working.
SnS = Sensors out of balance. If alternating with temp, may be temporary condition. If display shows only this message (blinking) spa is shut down.
HFL = Substantial difference between temperature sensors detected. Could indicate a flow problem.
LF = Persistent low flow problems. (Displays on the 5th occurrence of 'HFL' message with 24 hours). Heater is shut down, but other spa functions run normally.
dr = Inadequate water detected in heater.
dry = Inadequate water detected in heater. (Displays on third occurrence of 'dr' message). Spa is shut down.
Pr = When spa is first actuated, it will go into Priming Mode.
ILOC = Interlock failure - possible pump or ozone spike .
(---) =Unknown water temperature. (Displays when first powered up after refill).
Std = Spa operating in Standard Mode.
Ecn = Spa operating in Economy Mode.
SE = Spa operating in Standard-in-Economy Mode.

Coleman Hot Tub Error Code E03

Brett Aqualine

OH = Temp exceeds 118° F
Fr = Freeze condition - temp below 40° F
FL = Pressure switch failure
EO = Shorted temp sensor
E1 = Open temp sensor
E2 = Shorted hi-limit sensor
E3 = Open hi-limit sensor
E4 = Shorted flow switch
E7 = Improper electrical connection

CTI

th1/39 = On startup indicates temperature probe problem.
th2/current temperature = On startup indicates temperature probe problem.
th3/39 = On startup indicates water temperature less than 39° F.
OH = Overheating, water over 112° F. System will restart when temp. drops.
hot = Overheating, water over 112° F. System will restart when temp. drops.
HL = High limit switch tripped.

Dream Maker Hot Tubs

OH = Overheat 108° F, spa is deactivated. Do not enter the water.
FL = Flow. Pressure switch is not working.
SN = Non functional high temperature sensor. Heater is deactivated.
F2 = 4 hours daily filtration
F4 = 8 hours daily filtration
F6 = 12 hours daily filtration
FC = continuous filtration

EasyPak

C = Celsius
CL = Current Time of Day
ECdu = Economy Mode Duration
Econ = Economy Mode Turn On
F = Fahrenheit
Fldu = Filter Cycle Duration
Flon = Filter Cycle Turn On
FLC = Pressure Switch Alarm
FLO = Pressure Switch Alarm
FrEE = Freeze Protection Alarm
HL = High Temperature Alarm
Loc = Panel / Keypad Locked
PrH = Temperature Sensors Alarm
Prr = Temperature Sensors Alarm
Tu = Temperature Set Celsius
Tu = Temperature Set Fahrenheit

Download God Of War - Chains Of Olympus ROM for Playstation Portable(PSP ISOs) and Play God Of War - Chains Of Olympus Video Game on your PC, Mac, Android or iOS device! God Of War - Chains Of Olympus is a Playstation Portable emulator game that you can download to havev fun with your friends. God Of War - Chains Of Olympus file size - 1.1GB is absolutely safe because was tested by virustotal.com. WE ALSO RECOMMEND YOU TO TRY THIS GAMES God Of War. S UCUS-98653 G God of War Chains of Olympus C0 Infinite Health L 0x2033080C 0x4FFFFFFF C0 Infinite Magic L 0x20330830 0x7FFFFFFF C0 Max Chains of Olympus L 0x20330718 0x00000000 L 0x2033071C 0x00000000 L 0x20330720 0x00000000 L 0x20330724 0x00000000 C0 Max Efreet L 0x203307E0 0x00000000 L 0x203307E4 0x00000000 C0 Ultra Hyper. Game: God of War - Chains of Olympus (Europe) File Name: God of War - Chains of Olympus (Europe).7z File Size: 1.01 GB Genre: Adventure System: Sony Playstation Portable Downloads: 4,643,480 Rating: (4.83 /5, 45,896 votes) Top 25 PSP ROMs. God of War - Ghost of Sparta. God Of War Chains Of Olympus Walkthrough Complete Game PSP/PS3 Playlist http://www.youtube.com/playlist?list=PLmL2S1tVD9V0miFXTSmt9-NOCYEB60&feature=edit. God of war chains of olympus apkpure iso.

Gecko

FLO = Pressure switch failure, switch open
FLC = Pressure switch failure, switch closed
Prr = Temp sensor failure
Prh = Hi-limit sensor failure
HL = Sensor measuring 119° F
FrE = Possible freeze condition detected

Hercules

OH = Spa temp exceeds acceptable limits
FLO = Flow problem
ICE = Freeze condition detected
SN1 = Hi-limit sensor failure
SN2 = Temp sensor failure

Hurricane

PS = Flow or pressure switch failure
SH = Shorted sensor
OP = Open Sensor
LO = Temp below 60° F - freeze
HL = Temp above 118° F

Hydro-Quip

C = Celsius
CL = Current Time of Day
ECdu = Economy Mode Duration
Econ = Economy Mode Turn On
F = Fahrenheit
Fldu = Filter Cycle Duration
Flon = Filter Cycle Turn On
FLC = Pressure Switch Alarm
FLO = Pressure Switch Alarm
FrEE = Freeze Protection Alarm
HL = High Temperature Alarm
Loc = Panel / Keypad Locked
PrH = Temperature Sensors Alarm
Prr = Temperature Sensors Alarm
Tu = Temperature Set Celsius
Tu = Temperature Set Fahrenheit

Jacuzzi Whirlpool

OH = Overheat Protection (Heater is deactivated, pumps low speed is activated).
COOL = Spa water is more than 20° F cooler than the temperature set point.
FLO* = Flow Switch (heater is deactivated. Pump may also be deactivated).
Hold = Panel sensors have been pressed too many times in a short period of time.
HOT = Circuit Board temperature has exceeded acceptable limit.
ICE = Freeze protection. No action is necessary.
I CE2 = Freeze protection. No action is necessary.
PnL = Communication between the panel and circuit board is faulty.
---- = 'Watchdog' (spa is deactivated) A problem has been detected.
Sn1 = Open sensor (heater is deactivated) or Shorted sensor (spa is deactivated).
Sn3 = Open or shorted sensor ( heater disabled).
FLO2 = Closed or shorted flow switch on system startup

Coleman Hot Tub Error Code E03

Maytag Error Code E03

Pinnacle

OH = Temperature has exceeded 110° F
SN = Sensor failure
FL = Flow/pressure switch stuck in closed position

Spa Builders

Sn1 = Nonfunctional high temperature sensor. Heater is deactivated.
Sn2 = Nonfunctional temperature sensor. Heater is deactivated.
FL1 = Water flow problem, inhibited or pressure switch malfunction. Check for proper spa water level and ensure pump is primed. Check for clogged filter.
FL2 = Pressure switch problem. Switch closed while pump is deactivated.
COL = Cool condition. If water temperature drops 20°F below set temperature, low speed pump and heater activates to bring temperature within 15° of set temperature.
ICE = Freeze condition. 55°F detected. Low speed pump and heater will activate until spa reaches 65°F.
OH = High temperature condition, has reached 110°F. Do not enter the spa. Low speed pump (and air blower if so equipped) will activate to assist in lowering temperature.
--- = 'Watchdog'. Water temperature has reached 118°F. Entire system is disabled. Contact qualified service technician.

Sundance Spas

ILOC = Interlock failure - possible pump or ozone spike
FLO = Pressure switch malfunction or Flow switch malfunction (system specific)
Hold = Panel buttons pressed to many times to quickly
HOT = PCB temperature above acceptable limit - air blower on
ICE = Potential freeze condition
Pnl = Communication between PCB and panel interrupted
Sn1 = Hi-limit sensor failure
Sn3 = Temp sensor failure
---- = 'Watchdog' (spa is deactivated) A problem has been detected

Vita Spas

HiLi = Water temp over acceptable limit
BJ2P = Pump/Blower purge - normal condition
FP = Freeze protect-temp under acceptable condition
SS=0; SS=S; LS=O; LS=S = Multiple causes; open sensors, bad connection to panel, improper voltage, etc.

Coleman Hot Tub Error Code E03

'Very pleased with the ease of installation and all the diagnostic features that other spa packs did not even have. Like the name says, it was quite easy to install.'

James Hirsch
Buffalo, NY

The Cover Guy

Download our FREE

Download Rhythm with Tabla & Tanpura PC for free at BrowserCam. PSS Labs published the Rhythm with Tabla & Tanpura App for Android operating system mobile devices, but it is possible to download and install Rhythm with Tabla & Tanpura for PC or Computer with operating systems such as Windows. Tanpura app for pc. New tanpura resonance, mainly for using with the new sounds. Let the resonance of the strings playing while starting a new cycle of tanpura. Improved license management compatibility with Windows Vista and Windows 7. Warning: iTabla Desktop will ask for your license. Just give it the same license you got for the previous version. Download this app from Microsoft Store for Windows 10 Mobile, Windows Phone 8.1, Windows Phone 8. See screenshots, read the latest customer reviews, and compare ratings for tabla. If you follow the above steps correctly, you should have the Sur Sadhak App ready to run on your Windows PC or MAC. Download Sur Sadhak:Tabla,Tanpura for Indian Vocal Practice For PC Download Sur Sadhak APK 1.3.5 for PC. Rhythm with Tabla & Tanpura for PC (Windows 10/8/7 & Mac) As mentioned earlier, we will be using an Android emulator to Download and Install Rhythm with Tabla & Tanpura on Windows 10 / 8 / 7 or Mac PC. Bluestacks app player is the most popular among all the emulators available.

Guide Now

Coleman Hot Tub Error Code E03

This week we have a question from one of our hot tub customers about hot tub repair, and the E6 or Error 6 on their hot tub top side control. The E6 error code on your hot tub usually refers to a reduction or stoppage of water pressure. The E6 code is a warning that there is not sufficient water flow for the power pack to continue operating without possible damage. The power pack must shut down for self preservation. If you do not have enough water flow the area with the heating element will over heat and melt.

Komatsu Error Code E03

The cause of an E6 error code in hot tubs varies greatly but here are a list of things to consider and check.

Bosch Dryer Error Code E03

  • Filter – The most common reason for an E6 in a hot tub is dirty hot tub filters. It is so important for the operation of your hot tub that you clean your filters weekly with a rinse and every 3 – 6 months with a full degreaser bath to remove the residue. If the filters are dirty the water flow through your hot tub power pack will be impeded and you will have an E6 code and the hot tub will shutdown. This can have disastrous results in the winter if your power pack stops operating and goes unnoticed.
  • Suction or Intakes in your hot tub – Another possibility to the restriction of water flow can be debris at the suction areas of the hot tub. Make sure these areas are clear from debris.
  • Air Lock – Another common issue is after filling up your hot tub after draining it or when first starting our you have an air lock in your line. The way to remove this air lock is by either opening the union closest to your pump, or when you are filling your hot tub force the water through your skimmer basket. The air lock most commonly is in the heater element area.
  • Shut Off Valves – This can be overlooked from time to time, make sure your shut off valves are all open when you start up your power pack.
  • Power Pack – The last possible issue that you can have with an E6 error code on your hot tub is a faulty pump. The possible problems your pump can have is debris in your impeller, the shaft being seized, or a capacitor issue. Either way you would hear a constant hum from the motor with no water flow. At this point you would want to call in a hot tub service specialist to help.

Whirlpool Duet E03 Error Code

Hopefully this helps our hot tub community with the E6 or Error 6 code on your hot tub.